电气规格: |
|||||
产品型号 |
SAK100M-S12 |
SAK100M-S24 |
SAK100M-S36 |
SAK100M-S48 |
|
输出特性 |
输出电压 |
12V |
24V |
36V |
48V |
输出电流范围 |
0~8A
|
0~4.1A |
0~2.7 A |
0~2.1A |
|
功率范围 |
100W |
100W |
100W |
100W |
|
纹波 & 噪声(典型值) 注2 |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
|
输出电压精度 |
±2.0% |
±2.0% |
±2.0% |
±2.0% |
|
输出电压调节范围 |
11.9~15.2V任调 |
22.9~29V任调 |
33~39V任调 |
45~50.5V任调 |
|
源效应 |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
负载效应 |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
启动上升时间 (典型值) |
10ms/230VAC 30ms/115VAC at full load |
||||
输出保持时间 (典型值) |
40ms/230VAC 15ms/115VAC at full load |
||||
效率 (典型值) |
75% |
81% |
84% |
85% |
|
输入特性 |
输入电压范围 |
85 ~ 265VAC |
|||
输入频率 |
47 ~ 63Hz(440Hz Max) |
||||
输入电流 (典型值) |
1.9 A / 115VAC 0.96 A/ 230VAC |
||||
冲击电流 (典型值) |
冷启动 30 A / 115 VAC 60 A / 230 VAC |
||||
漏电流 (典型值) |
<1mA at 230VAC/50Hz |
||||
保护特性 |
过流、短路保护,故障排除后可自恢复 |
||||
工作环境 |
工作温度 |
工业级-25 ~+70 ℃、军品级-40~+70 ℃(后缀加J) |
|||
工作湿度 |
85% .RH max |
||||
存储温度 |
–40 ~ +105, 10 ~ 95% RH |
||||
温漂系数 |
0.03%/ (0~50℃) |
||||
震动系数 |
10~500Hz,2G10min./1cycle, 60min.each along X,Y,Z axes |
||||
安全与电磁兼容 (注 3 ) |
安全标准 |
符合UL1012 |
|||
绝缘电压 |
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC |
||||
绝缘电阻 |
I/P-O/P,I/P-FG,O/P-FG:>100MOhms/500VDC25℃70% RH |
||||
传导与辐射 |
符合 EN55011, EN55022 (CISPR22) |
||||
其它 |
MTBF |
200K hrs min. MIL-HDBK-217F(25) |
|||
尺寸 |
129*98*38mm (L*W*H) |
||||
重量 |
0.52Kg |
||||
备注 |
1. 以上数据除特殊说明外,都是在TA=25oC,湿度<75%,输入标称电压230Vac和输出额定负载时测得; |
||||
2. 纹波与噪声是使用300mm的双绞线,同时终端并联一个0.1uF的高频陶瓷电容和一个47uF的电解电容测得的。. |
|||||
3. 电源在系统内是被视为元器件,需结合终端设备进行电磁兼容相关确认 |